  description the psd series photoelectric smoke detectors respond to a broad spectrum of both flaming and smoldering fire conditions. they incorporate state-of-the-art, solid-state, low-voltage circuitry and are designed for 2-wire and 4-wire installation with the proper base. high signal-to-noise ratio permits a significant reduction in light baffling, thereby improving smoke entry characteristics while reducing nuisance alarms. three separate detection identifications are required for alarm confirmation. this three level detection sequence reduces nuisance alarms. each identification is made at two second intervals. digital storage of the previous identifications provides positive and reliable detection. functional testing is accomplished by means of a test magnet. this magnet test meets the requirement of the u.l. sensitivity test feature. in addition, the actual sensitivity of the detector may be measured in direct percent per foot obscuration with a sensitivity tester and standard voltmeter without the necessity of removing the detector. the companion model psd-7156 includes a thermistor heat detector with a 135 o f setpoint and is independent of smoke detector circuitry. the psd photoelectric detectors may be interchanged with model cpd-7051 ionization detectors. optional bases are available for remote test, remote indication, 4-wire operation and/or control functions. see table i. in addition, an ma-001 adapter is available to enable the PSD-7155 and psd-7156 to mount in existing model cpd series bases. approvals ul (std 268) s1913 c.s.f.m. 7272-1076:117 new york city mea 346-92-e factory mutual 0w3a2.ay features  low profile appearance  high air velocity rating  suitable for mounting inside ducts  flashing led for visual supervision  remote and local functional test capability  in-place sensitivity measurement in percent per foot obscuration  optional 135 o f thermistor heat detector  two and four-wire low current design  non-polarized  three level alarm verification  emi/rfi resistant PSD-7155 series photoelectric smoke detector 16 southwest park, westwood, ma 02090 usa tel: (781) 471-3000 fax: (781) 471-3099 technical specifications nominal sensitivity 3.25 %/ft. standby voltage 10.2 - 36.8 vdc (24 vdc nominal) standby current 55 ua. (typical) 100 ua. peak @ 24 vdc operating temp. 32 o to 100 o f(0 o to 38 o c ) per ul 268 humidity 0 - 93% rh non-condensing air velocity 4,000 ft/minute max. area of coverage 30 ft. centers (900 sq. ft. max.) (smooth ceilings) storage temperature -20 o to 180 o f (-29 o to 82 o c) finish off-white texture, high impact plastic. insect screen polyester, 0.0280" mesh size. 54% total open screen area. 9020-0304/ver. 1.8
installation installation is simple because of the nonpolarized connection. the detector mounts to the base by a twist-to-lock action. a removable locking tab secures the head to the base to provide a degree of vandal resistance. units mount directly to a 3, 3.5 or 4-inch octagonal box, 3-inch round box, or 4-inch square box. no adapters required. note : the number of two-wire smoke detectors which can be accommodated per zone varies with different control panels. consult the control panel instruction manual to determine the capacity. refer to n.f.p.a. 72, ?smoke sensing fire detectors? for spacing, location of detectors and other guidelines. maintenance cleaning programs should be adapted to the individual environment in conformance with nfpa standard 72. we recommend, at the least, an annual cleaning of dust from the detector head by using the suction of a vacuum cleaner. refer to the installation instructions for the complete procedure. 2of2 9020-0304 dimensional data table i - detector base options model compatibility description identifier 2-wire fe51a connects to 2-wire detection circuit via screw terminals. 2wrlt fe52a as above except has output for remote test and led indicator. 2wrb fe55a connects to 2-wire detection circuit via wire-leads. has remote test feature, led indicator and spdt auxiliary relay rated 1 amp. @ 30 vdc. minimum alarm current: .019 amp. (maximum of 1 per zone) 4wrb n/a connects to 4-wire detection circuit via wire-leads. equipped with spdt auxiliary relay rated 2 amps. @ 30 vdc. minimum alarm current .015 amp. specifications are provided for information only, are not intended to be used for installation purposes, and are believed to be accurate. however, no responsibility is assumed by fire control instruments, inc. for their use. specifications subject to change without notice. 1997 all rights reserved ordering and technical information model compatibility description identifier PSD-7155 p55fe1 photoelectric smoke detector. psd-7156 p56fe1 photoelectric smoke detector with 135 o f thermistor heat detector. ma-001 adapter to allow mounting to existing cpd series bases. 2wrm replacement relay component of 2wrb. 4wrm replacement relay component of 4wrb. 2040-24 end of line supervisory relay, 24 vdc. rai-2 remote alarm indicator. rcm-500 remote alarm indicator/key test switch. warning : to prevent detector contamination during construction, smoke detectors must be protected from dust and contamination until area is clean and dust free. see nfpa 72. caution : do not attempt disassembly of the factory sealed smoke detector. this assembly is sealed for your protection and is not to be opened for servicing. opening of the detector will void the warranty.


▲Up To Search▲   

 
Price & Availability of PSD-7155

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X